色欲AV蜜桃一区二区三_18禁免费高清啪啪网站_精品国产香蕉伊思人在线_国产成人精品一区二区三区无码_99精品久久久中文字幕

  設(shè)為主頁 加入收藏 English
 
 
 
 產(chǎn)品資料
 技術(shù)資料
 參考文獻(xiàn)
 
 

Introducing a nested phase change agent with an acoustic response that depends on electric field: A candidate for myocardial perfusion imaging and drug delivery

文件大小:1.78
發(fā)布時(shí)間:2018-06-20
下載次數(shù):0

作者Michael Cimorellia, Brett Angelb, Aaron Fafarmana, Andrew Kohutb, Benjamin Andriena, Kyle Barretta, StevenWrenna

a    Chemical and Biological Engineering, Drexel University, Philadelphia, PA, United States

b    Cardiology, Drexel University College of Medicine, Philadelphia, PA, United States

 

摘要:We present a voltage-sensitive phase change agent comprising an aqueous emulsion of surfactant-coated liquid perfluorocarbon droplets nested within a negatively charged phospholipid bilayer. The sensitivity to voltage allows, via exposure to an electric field, acoustic activation of the perfluorocarbon droplets at an ultrasound intensity that is otherwise insufficient to cause activation. The result is a phase change agent for which activation depends not on ultrasound intensity but rather on the presence of an electric field. Accordingly, we offer the first enhanced ultrasound contrast agent (Electrast) that takes advantage of the electrical activity of the heart and leads to selective activation at a fixed mechanical index (MI). Being voltage-sensitive, Electrast activates selectively in the coronary circulation, giving enhanced ultrasound contrast within the myocardium while leaving other regions largely unenhanced. Specifically, in a closed chest swine study, the contrast enhancement between the myocardium and the left ventricle increased by 36.4?dB ±0.2 upon injection of a charged, nested PCA formulation at a fixed MI of 0.9 (GE Vivid i). Similar enhancement was observed in rats, and the contrast-to-tissue ratio increased by nearly 10?dB at an MI of 0.28 upon exposure to an electric field of 1?V/cm in a tissue-mimicking phantom. Additionally, ultrasound-induced leakage of calcein, a water-soluble fluorescent dye, from a nested, charged PCA formulation more than doubled at a peak negative pressure of 0.5?MPa upon exposure to an electric field of 0.25?V/cm. These results suggest that Electrast, a voltage-sensitive phase change agent, is a candidate for myocardial perfusion imaging using ultrasound.

下載地址下載地址1
 
上海市普陀區(qū)嵐皋路567號(hào)1108-26室 電話:021-62665073 400-718-7758 傳真:021-62761957
美國布魯克海文儀器公司上海代表處 版權(quán)所有  管理登陸 ICP備案號(hào):滬ICP備19006074號(hào)-2 技術(shù)支持:化工儀器網(wǎng)